UNI-T UT209 Especificações

Consulte online ou descarregue Especificações para Multímetros UNI-T UT209. UNI-T UT209 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - OPERATING MANUAL

Model UT209OPERATING MANUAL

Página 2

International Electrical SymbolsAC (Alternating Current)DC (Direct Current)AC or DCGroundingDouble InsulatedWarning. Refer to the Operating ManualDefi

Página 3

Figure 1The Meter Structure (see figure 1)Hand Guards: to protect user’s handfrom touching the dangerous area.Trigger: press the lever to open thetra

Página 4 - Overview

Press SELECT button to select the alternate functions includingV , andButton Operation PerformedSELECTPMAX/PMINPress HOLD to enter the Ho

Página 5 - Unpacking Inspection

Button Operation PerformedHOLDHzZEROPress ZERO to display the present value as stored value anddisplay zero. After that, all the measureme

Página 6 - Safety Information

SELECT MAX/MINHOLDHzZERO%Hz44A1000A40A1000AN/AN/AN/AN/AN/AN/AN/ARotary SwitchPositionsVFunctional ButtonsN/AN/AThe Effectiveness of Functional Button

Página 7 - Rules For Safe Operation

Figure 2Display Symbols (see figure 2)Model UT209: OPERATING MANUAL14

Página 8

Number Symbol Meaning1234567891011Hz,kHz,MHz,k ,MPMAXPMINZEROHz: Hertz. The unit of frequency.KHz: Kilohertz. 1 x 103 or 1000 her

Página 9

Number Symbol Meaning1213141516171819The battery is low. Warning: To avoid false readings, whichcould lead to possible electr

Página 10 - Model UT209: OPERATING MANUAL

A.DC/AC Voltage Measurement (see figure 3)To avoid harms to you or damages to the Meter from eletric shock, do notattempt to measure voltages higher t

Página 11

To measure DC/AC voltages, connect the Meter as follows:Insert the red test lead into the V Hz terminal and black test lead into the COMterminal.Set

Página 12 - Functional Buttons

Table of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical SymbolsThe Meter StructureFu

Página 13

B.Measuring Resistance (see figure 4)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-vol

Página 14

3. Connect the test leads across with the object being measured.The measured value shows on the display.NoteTo obtain a more precise reading, you coul

Página 15 - (see figure 2)

C. Testing Diodes (see figure 5)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-voltage

Página 16

Insert the red test lead into the V Hz terminal and black test lead into the COMterminal.Set the rotary switch to Press SELECT to switch to measure

Página 17

D. Testing for Continuity (see figure 6)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-

Página 18 - Measurement Operation

a circuit under test is higher than 100NoteWhen continuity testing has been completed, disconnect the connection betweenthe testing leads and the cir

Página 19

E. Frequency Measurement (see figure 7)To avoid harms to you or damages to the Meterfrom eletric shock, do not attempt to measurevoltages higher than

Página 20

NoteThe maximum amplitude must not exceed 30Vrms.When frequency measurement has been completed, disconnect the connectionbetween the testing leads and

Página 21

F. DC Current Measurement (see figure 8)The operating temperature must be 0 ~40when measuring current.The measurement ranges of current are: 40A and

Página 22

not display zero. When the testing current is greater than 400A , it is notnecessary to zero.Hold the Meter tight, don’t release. The Hall componen

Página 23

Title Page3032333334353536373838394040414142 G. AC Current MeasurementSleep ModeSpecifications A. General Specifications B. Environmental

Página 24

Note Press ZERO to display the present value as stored value and display zero. After that, all the measurement result displayed will automatic

Página 25

G. AC Current Measurement (see figure 9)The operating temperature must be 0 ~40when measuring current.The measurement ranges of current are: 40A a

Página 26

NoteWhen measuring AC current range, It may have unstable or wrong sensed readings,it will not affect measurement result.Change to AC:Couple AC and Tr

Página 27

Sleep ModeTo preserve battery life, the Meter automatically turns off if you do not turn the rotaryswitch or press any button for around 30 minutes.Th

Página 28

l Maximum Voltage between any Terminals and grounding: Refer to different range input protection voltage.l Display: 3 3/4 digits LCD display, Ma

Página 29

l Battery Life: typically 150 hours (alkaline battery)l Dimensions: 285.3mm x 105mm x 44.5mml Weight: Approximate 533g (battery included)B. Environme

Página 30

Accurate SpecificationsAccuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 23 5Relative humidity: 85%R.HTemperature co

Página 31

B. AC VoltageRange400mV4V40V400V600VResolution0.1mV0.001V0.01V0.1V1VAccuracy(1.2%+20)(1.2%+5)(1.5%+5)Overload protection600V DC/ACRemarks:Input Impeda

Página 32

Peak factor: 1.4~2.0, add 1.0% on the stated accuracyPeak factor: 2.0~2.5, add 2.5% on the stated accuracyPeak factor: 2.5~3.0, add 4.0% on the stated

Página 33 - Sleep Mode

D. Diode TestRange Resolution1mVAccuracy0.5V~0.8V (Opencircuit voltageapprox. 3.0V)Overload protection250VACE. Continuity TestRange Resolution0.1Accur

Página 34 - Specifications

OverviewThis Operating Manual covers information on safety and cautions. Please read therelevant information carefully and observe all the Warnings an

Página 35

Remarks:l Input Sensitivity as follows: When 100kHz: 300mV rms When>100kHz: 600mV rmsl Input amplitude a: 300mV a 30V rmsF. Fr

Página 36 - Accurate Specifications

G. DC CurrentRange40A1000AResolution0.01A1AAccuracy(2%+40)(2%+8)Overload protection 250VACH. AC CurrentRange40A1000AResolution0.01A 1AAccuracy(

Página 37

MAINTENANCEThis section provides basic maintenance information including battery replacementinstruction.Do not attempt to repair or service your Meter

Página 38

inflammable and strong magnetic field.To avoid false readings, which couldlead to possible electric shock orpersonal injury, replace the battery asso

Página 39

To replace the battery:.1. Turn the Meter off and remove all the connections from the input terminals2. Turn the Meter’s front case down.3. Remove the

Página 40

* END *This operating manual is subject to change without notice.Model UT209: OPERATING MANUAL44

Página 41

Copyright 2007 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Página 42 - MAINTENANCE

Item Description Qty1234English Operating ManualTest LeadTool Box9

Página 43

Safety InformationThis Meter complies with the standards IEC61010: in pollution degree 2, overvoltagecategory (CAT. II 600V, CAT. III 300V) and double

Página 44

Rules For Safe OperationTo avoid possible electric shock or personal injury, and to avoid possibledamage to the Meter or to the equipment under test,

Página 45

changeover of range shall be made during measurement is conducted toprevent damage of the Meter.Do not carry out the measurement when the Meter’s back

Página 46

When servicing the Meter, use only the same model number or identicalelectrical specifications replacement parts.The internal circuit of the Meter sha

Comentários a estes Manuais

Sem comentários