According to the specifications, maximum range is about 10 m (32.8 ft) in open air. Inside, the display
module lost signal at a distance of about 6 m (20 ft) and with two thick concrete floors between the
base station and the display module, so range is satisfactory.
The meter disassembled: safety features
The most important feature of a multimeter is, of course, its safety. With a voltage range of 1000 V
and a current range of 10 A, measurements can be quite dangerous. And what if the operator makes
an error, and the meter is accidentally exposed to an even higher voltage or current? A good
multimeter has one or more fuses inside to prevent damage to the meter, and a well-designed circuit
layout so no arcing will occur (up to a certain extent, of course). But, before I open up the Fluke 233,
let us look at the outside. Fluke has included a warning symbol on the display that lights if a
dangerous voltage is detected. The base station is also equipped with a warning light that has the
same function, so you are still warned if the display module is removed. When you turn on the
meter, the light blinks for a second, so you can verify it is still working. Fluke has thought this out
extremely well.
Now, let’s remove the cover of the base station, which is held together by four crosshead screws.
Inside, you can see a big, fat F11 fuse, which is rated for 1000 V and has an interrupt rating of 17 kA.
Because the meter has only one low impedance connector, only one fuse is necessary. Fluke sells
replacement fuses for 9.00 USD in their online shop. Although the fuse is quite expensive, you will
only need to replace it if you make an error while measuring.