Measurement Operation(6)
3. Set the rotary switch to an appropriate measurement
position in A range.
4. Break the current path to be tested. Connect the red
test lead to the more positive side of the break and
the black test lead to the more negative side of the
break.
5. Turn on power to the circuit.
The measured value shows on the display.
Note
l If the value of current to be measured is unknown,
use the maximum measurement position (20A) and
20A terminal and reduce the range step by step until
a satisfactory reading is obtained.
l When current measurement has been completed,
disconnect the connection between the testing leads
and the circuit under test.
E. Measuring Resistance (see figure 5)
( figure 5)
red black
Model UT50E: OPERATING MANUAL