UNI-T UT501 Manual de Instalação Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 26
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 7
DMX 512 TO MICROPLEX
In this application, DMX 512 is converted to Microplex..
CONNECTOR OPERATION
Microplex IN Not used
Microplex OUT Output Microplex (64 or 128)
DMX IN Input DMX 512
DMX out Pass through DMX 512
MIDI / Analog Not used
Luma-net Not Used
RS-232 Not Used
JUMPER LOCATIONS
P4 & 5 P7 JP6 & 7 JP8 & 9 JP10 JP11 JP12 JP13
CLOSED CLOSED N/A N/A 2-3 2-3 N/A 2-3
P6 P8 JP1 DMX OUT CABLE
*CLOSE TO TERM
DMX
N/A N/A JP4
DIPSWITCH POSITIONS
C1 C2 C3 C4 ADDRESS 1 - 7 A8
DN UP DN DN STARTING DMX CHANNEL FOR MICROPLEX BY 16 INCR. DN:64
Microplex channel 1 is equal to starting DMX channel. Address switch 1 - 6 sets starting DMX channel in
increments of 16. See chart at the end of this manual.
Microplex output is sent as either 64 or 128 channels, depending on the setting of switch A8.
*DMX should only be terminated internally if IF501 will be always last unit at end of DMX line. A better way
to terminate is to connect 120ohm resistor to a female DMX cable end (pins 2-3) and plug it into the pass-through
of the last unit on the DMX line.
INTERFACE UNIT
Software Revision 1.05, Version A DMX 512 TO MICROPLEX